Positioning of Coke Oven Machines

What is position misread protection?

The SPKV head checks the signal bits from the optical sensors and their parity. It also keeps a sequence of code plate numbers in memory – if it reads a different plate code than the correct one, it reports an error to the operator.

How is the automatic optics contamination check performed?

After removal from the code board, the light output of the optics is reduced (-30%, -15%) and the optical path is checked (signals must be switched). In case of an error, a message to the operator is displayed. This prevents an error in advance.